Marine
RV/Camping
Residential
Construction
Aviation
Industrial

Applications

ALARM MONITORING
ROOM TEMPERATURE MONITORING
SERVER ROOM TEMPERATURE MONITORING
GPS TRACKING
CONTROL AND TELEMETRY
PROCESS MULTIPLE COMMAND SEQUENCES
PEER TO PEER CONTROL
PHONE REMOTE CONTROL
TELEMETRY
SECURITY
The INSITE i2 ALERT can send alarms to up too 4 mobile phones when an event is detected. INSITE can even be programmed to escalate the call to up to 8 additional cell phone numbers after a user nominated delay until the alarm is acknowledged.

INSITE provides 8 switch contact inputs that alarm on any change to switch state. Any device that has a contact output or a suitable signal voltage, can be connected to these inputs and used to send an SMS text message warning on contact closure, contact opening, or both. Such as:

ALARM MONITORING


Detected Event
• Low/High Tank Level • Low/High Pressure
• Low/High Temperature • Power Failure
• Vending machine Alarm • Freezer/Cooler Room Temperature Alarm
• Server Room/Data Center Environment Alarm • Smoke Detector
• Communication System Failure • Bilge Float level/Pump activation Alert
• Vessel Moved Away From Dock Alert • System Failure Alert
• Switch State Change • Motion Sensor Detects Movement
• Security System Alarm

ROOM TEMPERATURE MONITORING

Don't put your valuable, temperature sensitive, cool room or freezer stock at risk! INSITE is a low cost, easy to install device that can alert you before your assets are spoiled or damaged.

You can connect up to 8 switch sensors with INSITE, such as temperature and humidity sensors, either hard wired or wirelessly using its built-in wireless receiver. INSITE will send you SMS alerts whenever a problem is detected.

Also built into INSITE is the ability to warn you when the power fails or resumes. You can even set a delay so it won't warn you every time there is a minor fluctuation.

If you have multiple temperature sensitive environments in close proximity to monitor, INSITE may be the perfect solution.

On many cool rooms & Freezers, INSITE can be hard wired to existing thermostats using the optional docking cradle.

If your cool rooms and freezers don't have thermostats and are in close proximity (about 10-15 meters) then you can use one of our optional wireless temperature probes to monitor each up to 8 temperature sensitive environments. (Install the probe in your cool room or freezer, set the high and low temperature set points, configure it to communicate with your INSTE, and as soon as the temperature goes outside your programmed range INSITE can send customizable SMS alerts to up to 4 users, plus an additional 8 users if you use the built-in Escalation feature. If you prefer you can configure it to wait for the temperature to remain out of range for up to 90 minutes before it sends you any alerts, to allow for a defrost cycle and cool room re-stocking times.
Back to Top

SERVER ROOM TEMPERATURE MONITORING

INSITE has built-in sensors that will generate alerts when the ambient temperature goes outside your configured high and low set points, or when the power fails.

INSITE i2 not only provides room temperature monitoring alerts, it can also send you a report at user defined intervals showing the maximum and minimum recorded temperature since the last report.

Also built into INSITE is the ability to warn you when the power fails or resumes. You can even set a delay so they won't earn you every time there is a minor power fluctuation.
Back to Top

GPS TRACKING

How much insurance excess and no-claim-bonus will you loose if your mobile asset is stolen?

USE INSITE i2 ALERT WITH OPTIONAL GPS TRACKING.

When a registered user sends INSITE and SMS message that includes the required text, INSITE will respond by sending an SMS message with its GPS Coordinates, speed, and direction using its own GSM SIM card.

Not only will the INSITE i2 provide GPS Coordinates in a Google Friendly format, it is loaded with features for monitoring and tracking moveable assets such as a boat, trailer, o motor home or motor cycle. It can be attached to virtually any other mobile equipment that needs to be tracked.
Back to Top

CONTROL AND TELEMETRY

Send you INSITE i2 and SMS from your GSM mobile phone to turn switches on and off, or to request a telemetry reading.

Remotely Control:
• Pumps
• Generators
• Garage/Other doors/Gates
• Security System Alarm
• Air Conditioning
• HVAC
• Ignition System
• Sirens
• Switches
• Roller Shutters
• Reticulation System
• Power/Lighting Circuits
• Another INSITE i2


Remotely Read Telemetry:
• Battery Voltage
• Tank Fluid Levels
• Pressure Levels
• Ambient temperature (Built in)
• Configured Meter Reading
Back to Top

PROCESS MULTIPLE COMMAND SEQUENCES

To make it easier to manage your assets, INSITE allows multiple embedded commands to be received within a single SMS message string. These commands can contain a request for remote telemetry and activate remote switches and functions.
Back to Top

PEER TO PEER CONTROL

INSITE i2 has the ability to perform Peer to Peer functions over two channels in both directions. That means two or more INSITE units can communicate with each other without any human or mobile phone intervention. A switch activation at one unit can be used to activate other functions remotely at other units, provided a small network delay can be tolerated. These can be used to control devices such as lights, pumps, motors, sirens and other equipment remotely.
Back to Top

PHONE REMOTE CONTROL

Just about anything can be activated by a switch can be remotely controlled by INSITE. Once connected, all you do is send an SMS message to your INSITE to start/stop your selected device. All control messages received by INSITE are confirmed after execution.
Back to Top

TELEMETRY

Two Telemetry INPUT Channels allow you to connect INSITE to a signal voltage, such as a battery or transducer output (e.g. pressure level sensor output). When you request a telemetry reading from a configured remote mobile phone, INSITE will return the voltage or transducer output reading.
Back to Top

SECURITY

All commands sent from remote phones are automatically checked against an access list of phone numbers for each device, so only a qualified phone will be given access to INSITE.

USE INSITE TO START/STOP REMOTE EQUIPMENT AND READ MEASUREMENTS SUCH AS OUTPUT VOLTAGES AND FLOW RATES.
Back to Top
Go to the Pricing page.
Marine Application Diagram
Industrial Application Diagram Commercial Application Diagram
Factory Office Monitoring Application Diagram